Operation Theorem
27
4.1.1 A/D Conversion Procedure
The A/D conversion is starting by a trigger source, then the A/D converter will
start to convert the signal to a digital value. The ACL-8111 provides three
trigger modes, see section 4.1.2.
The DRDY bit in the A/D data register (Base+5) will become to 0 once the
A/D conversion is completed and data on the Base+4 and Base+5 are ready.
A read data command on BASE+4 will automatically reset the DRDY bit to be
1 which means data is not ready on the Base+4 and Base+5. The A/D data
should be transferred into PC's memory for further using. The ACL-8111
provides three data transfer modes that allow users to optimize the DAS
system. Refer to section 4.1.3 for data transfer modes.
4.1.2 A/D Clock Sources (Trigger Modes)
In the ACL-8111, two Internal or one external clock sources can trigger A/D
conversion. The two internal sources are the software trigger and the timer
pacer trigger, which is controlled by the A/D operation mode control register
(BASE+11). The A/D operation modes combine the AD clock sources and
the data transfer mode together. Please also refer to the next section for
detail data transfer modes. The available operation modes include:
Software trigger and software polling transfer
Internal timer pacer and interrupt transfer
Internal timer pacer and software polling transfer
External trigger and interrupt transfer
External trigger and software polling transfer
Three AD clock sources (or trigger sources) are available in the ACL-8111.
Software trigger
The trigger source is software controllable in this mode. That is, the A/D
conversion is starting when any value is written into the software trigger
register (BASE+12). Under this mode, the timing of the A/D conversion is
fully controlled by software, it is suitable for low speed A/D conversion.
However, it is difficult to control the fixed A/D conversion rate except a timer
interrupt service routine is used and the software trigger is programmed
inside the interrupt service routines.