Adlink ACL-8112 Series Manual do Utilizador Página 75

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 92
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 74
C Language Library 67
7.10 _8112_AD_Set_Mode
Description
This function is used to set the A/D trigger and data transfer mode by
means of writing data to the mode control register. The hardware initial
state for the ACL-8112 is set as AD_MODE_1 software( internal) trigger
with program polling data mode.
A/D Mode Description
AD_MODE_0 External Trigger, Software Polling
AD_MODE_1 Software Trigger, Software Polling
AD_MODE_2 Timer Trigger, DMA Transfer
AD_MODE_3 External Trigger, DMA Transfer
AD_MODE_4 External Trigger, Interrupt Transfer
AD_MODE_5 Software Trigger, Interrupt Transfer
AD_MODE_6 Timer Trigger, Interrupt Transfer
AD_MODE_7 Not Used
Note: All analog input modes selection should match with the hardware
settings, which is described in the hardware users manual.
Syntax
int _8112_AD_Set_Mode(int ad_mode )
int _8112pg_AD_Set_Mode(int ad_mode )
Argument:
ad_mode:
AD trigger and data transfer mode
( please refer above table.)
Return Code:
ERR_NoError
ERR_BoardNoInit
ERR_InvalidMode
Vista de página 74
1 2 ... 70 71 72 73 74 75 76 77 78 79 80 ... 91 92

Comentários a estes Manuais

Sem comentários