Adlink DAQe-2006 Manual do Utilizador Página 19

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 92
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 18
Introduction 7
X CMRR: (DC to 60 Hz, Typical)
X Time-base source:
Z Internal 40MHz or External clock Input (fmax: 40 MHz,
fmin: 1 MHz, 50% duty cycle)
X Trigger modes:
Z Post-trigger, Delay-trigger, Pre-trigger and Middle-trigger
X Data transfers:
Z Programmed I/O, and bus-mastering DMA with scatter/
gather
X Input coupling: DC
X Offset error:
Z Before calibration: ±60mV max
Z After calibration: ±1mV max
Device Input Range CMRR Input Range CMRR
2010
±10V 90 dB 0~10V 89 dB
±5V 92 dB 0~5V 92 dB
±2.5V 95 dB 0~2.5V 94 dB
±1.25V 97 dB 0~1.25V 97 dB
2005
±10V 86 dB 0~10V 85 dB
±5V 88 dB 0~5V 88 dB
±2.5V 91 dB 0~2.5V 90 dB
±1.25V 93 dB 0~1.25V 93 dB
2006
±10V 87 dB 0~10V 86 dB
±5V 89 dB 0~5V 88 dB
±2.5V 91 dB 0~2.5V 91 dB
±1.25V 93 dB 0~1.25V 93 dB
2016
±10V 85dB 0~10V 86dB
±5V 88dB 0~5V 88dB
±2.5V 91dB 0~2.5V 92dB
±1.25V 95dB 0~1.25V 95dB
Table 1-3: CMRR: (DC to 60 Hz)