Adlink DAQe-2006 Manual do Utilizador Página 56

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 92
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 55
44 Operation Theory
Post-Trigger or Delay-trigger Acquisition with re-trigger
Use post-trigger or delay-trigger acquisition with re-trigger
function in applications where you want to collect data after
several trigger events. The number of scans after each trigger
is specified in PSC_counter, and users could program
Retrig_no to specify the re-trigger numbers. Figure 4-12 illus-
trates an example. In this example, two scans of data is
acquired after the first trigger signal, then the card waits for the
re-trigger signal (re-trigger signals which occur before the first
two scans is completed will be ignored). When the re-trigger
signal occurs, two more scans are performed. The process
repeats until specified amount of re-trigger signals are
detected. The total acquired data length = number of enable-
channel * PSC_counter * Re-trig_no.
Figure 4-12: Post trigger with re-trigger
Vista de página 55
1 2 ... 51 52 53 54 55 56 57 58 59 60 61 ... 91 92

Comentários a estes Manuais

Sem comentários