Operation Theory 33
Figure 4-2: Single Command Timing
The base scan time table is as follows, N is the range of total IDs.
Half Duplex Full Duplex Maximum Length
3M 118 us x N 60.7 us x N 400 meters
6M 59 us x N 30.4 us x N 200 meters
12M 29.5 us x N 15.2 us x N 100 meters
Table 4-1: Base Scan Times