42 Operation Theory
There are several parameters that need to be set in order to make
a S-curve move. They are:
X Pos: target position in absolute mode, in units of pulses
X Dist: moving distance in relative mode, in units of pulses
X StrVel: start velocity, in units of PPS
X MaxVel: maximum velocity, in units of PPS
X Tacc: time for acceleration (StrVel -> MaxVel), in units of
seconds
X Tdec: time for deceleration (MaxVel -> StrVel), in units of
seconds
X VSacc: S-curve region during acceleration, in units of PPS
X VSdec: S-curve region during deceleration, in units of PPS
Figure 4-9: S-curve Profile Motion
Normally, the accel/decel period consists of three regions, two
VSacc/VSdec curves and one linear. During VSacc/VSdec, the
jerk (second derivative of velocity) is constant, and, during the lin-
ear region, the acceleration (first derivative of velocity) is constant.
In the first constant jerk region during acceleration, the velocity
goes from StrVel to (StrVel + VSacc). In the second constant jerk
region during acceleration, the velocity goes from (MaxVel –
StrVel) to MaxVel. Between them, the linear region accelerates
Vista de página 51